Nom De Marque: | kimoems or OEM |
Numéro De Modèle: | Se référer aux paramètres |
MOQ: | 20pcs |
Conditions De Paiement: | T / t |
1/1 High Frequency UPS Single Input Single Output 1kva To 10kva
True double-conversion online UPS
●Output power factor 1.0
●User-friendly and easy-shift LCD display
●ECO and advanced ECO mode for energy saving
●Emergency Power Off Function (EPO)
●Efficiency 95.5%
●Charging Current Max 12Amp
●DSP technology applied
●Active input power factor correction 0.99
parameters
Model |
1KVA |
2KVA |
3KVA |
|||||
Rated Power |
900W/1000W |
1800W/2000W |
2700W/3000W |
|||||
Input |
Wiring |
L+N+PE |
||||||
Rated Voltage |
208/220/230/240Vac |
|||||||
Voltage Range |
110~300Vac |
|||||||
Frequency |
50/60±6Hz(default),±10Hz( Adjustable) |
|||||||
Power Factor |
≥0.99 |
|||||||
Generator Compatibility |
Available |
|||||||
Output |
Wiring |
L+N+PE |
||||||
Rated Voltage |
208/220/230/240Vac,Factory Preset:220Vac |
|||||||
Output Voltage Regulation |
±1% |
|||||||
Frequency |
Online Mode: Follow Grid Frequency;Battery Mode:50/60±0.1Hz |
|||||||
THD |
Linear Load≤2%,Non-Linear Load≤5%(PF=0.8) |
|||||||
Power Factor |
0.9/1.0(Optional ) |
|||||||
Switching Time |
0ms |
|||||||
Overload |
AC Mode:1102%~110% 30mins then transfer to bypass, 110%~130% 10mins & transfer to bypass, 130%~150% 30s, ≥150% 200ms transfer to bypass, Load≤70% recover to inverter mode. |
Battery Mode:102%~109% 1minute backup then shutdown, 110%~130% 10s then shutdown,130%~150% 3s , ≥150% 200ms,(under BAT mode UPS will be closed after 1mins when INV. Turn off) |
||||||
Crest Ratio |
3:1 |
|||||||
Efficiency |
Online Mode |
94.5%@220Vac |
95.5%@220Vac |
|||||
Battery Mode |
89.5% |
91.5% |
||||||
Battery and Charger |
Battery Type |
Lead Acid Maintenance Free Battery / Lithium battery |
||||||
Standard Model |
2PCS |
2PCS |
6PCS |
|||||
Long-run Model |
3PCS |
6PCS |
8PCS |
|||||
Battery over Voltage |
N*13.65Vdc(1±1%) |
|||||||
Battery under voltage |
10V*N@Load>50% |
|||||||
Shutdown Protection |
Available |
|||||||
Over-charging Protection |
Available |
|||||||
Charging Form |
2 Stages/ 3 Stages Charging |
|||||||
BAT Abnormal Alarm |
Available |
|||||||
Charging Current |
1-12A Adjustable |
|||||||
Communication |
Port |
RS232( Optional SNMP,USB,EPO) |
||||||
Environmen |
Ambient temperature |
0~40℃ |
||||||
Humidity |
20%~95% (No condensing) |
|||||||
Storage temperature |
-15~60℃ (Battery:0~40℃) |
|||||||
Altitude |
The altitude should not exceed 1000m, and the height above 1000m should be reduced to a maximum of 4000m. Refer to IEC62040 |
|||||||
Noise (dB) |
≤50db |
|||||||
D×W×H(mm) |
380*438*88mm |
|||||||
Net Weight(kgs) |
5.6kg |
9.5kg |
6.15kg |
14.5kg |
6.25kg |
20.30kg |
||
Certification |
EN/IEC 61000, EN/IEC 62040, GB/T 7260, GB/T 4943, YD/T1095, TLC |